Yoonseok Kim 1 Article
Catheter Fracture of a Totally Implantable Venous Device Due to Pinch Off Syndrome in Breast Cancer: A Case Report
Yoonseok Kim
Kosin Med J. 2016;31(2):167-172.   Published online January 20, 2016
DOI: https://doi.org/10.7180/kmj.2016.31.2.167
  • 1,531 View
  • 7 Download
  • 1 Citations
Abstract PDFPubReader   ePub   
Abstract

Totally implantable venous devices are used in medical care for parenteral nutrition, vascular access, administrating chemotherapeutic agents and so on. Although the large variety of catheter complications, catheter fracture is a rare but serious complication. The pinch off syndrome is caused by the compression of the catheter between the clavicle and first rib, and may lead to fracture and possible dislocation of the catheter. We report here the case history of a patient with metastatic breast cancer who developed a rare complication of subclavian catheter fracture as a consequence of pinch off syndrome.

Citations

Citations to this article as recorded by  
  • Pinch-off syndrome ou syndrome de la Pince Costo-Claviculaire
    E.A. Allassane, M. El Hammoumi, M. Bhairis, F. El Oueriachi, E.H. Kabiri
    Revue de Pneumologie Clinique.2018; 74(6): 492.     CrossRef